Effect of Intraoperative Infusion of Esketamine on Quality of Postoperative Recovery in Patients Undergoing Laparoscopic Bariatric Surgery: A Randomized Controlled Trial.
Abstract
<h4>Introduction</h4>This study aims to evaluate the efficacy of esketamine on postoperative recovery quality after laparoscopic bariatric surgery.<h4>Methods</h4>Patients (n = 74) scheduled for laparoscopic bariatric surgery were randomly divided into two groups: the esketamine group (group E: 0.5 mg/kg/h infusion, i.e., 0.2 mL/kg/h) or the control group (group C: 0.2 mL/kg/h normal saline infusion). The infusions were stopped 20 min before the end of the procedure. The primary outcome was the Quality of Recovery-40 (QoR-40) score on postoperative day 1 (POD 1). The secondary outcomes included QoR-40 scores on PODs 2 and 7, Numeric Rating Scale (NRS) on PODs 1, 2, and 7, time to extubation, additional postoperative analgesic use, length of hospital stay, and time to first exhaust. Additonally, the safety indices were also recorded, including hemodynamic profile, perioperative anesthesia index (Ai), utilization of vasoactive drugs or urapidil, and side effects.<h4>Results</h4>All in all, 70 of the 74 patients completed the study, 35 in each group. The difference of QoR-40 scores on POD 1 was both statistically and clinically significant [difference 7.21, 95% confidence interval (CI) 5.17, 9.25, p < 0.001]. The difference of QoR-40 on POD 2 was statistically significant but clinically insignificant (difference 4.81, 95% CI 2.69, 6.92, p < 0.001). The difference of NRS scores on POD 1 was statistically significant (difference -1.23, 95% CI -2.36, -0.10, p = 0.033). Compared with group C, group E had a lower utilization rate of phenylephrine and higher Ai values (p < 0.05). There was no statistical difference between the two groups on other measures.<h4>Conclusion</h4>Continuous ketamine infusion seems to be safe and well tolerated in laparoscopic bariatric surgery. It improved the quality of postoperative recovery and reduced pain on POD 1. In spite of the increased Ai value during the surgery, it also provided better hemodynamics with less usage of phenylephrine.
Topics & conditions
Detected automatically by Psychedelic Commons from the title and abstract, not labels from the source. They may be incomplete.
Keywords
Psychedelic Commons aggregates metadata from open sources and links back to the original. Rights remain with the authors and publishers. Something wrong with this record? Report a problem.